Case of the Week ·
Case Archive ·
Submit a Case
Number 07-11: Valvular disease by CMR
Case from: Niall G
Keenan, Agata Grasso and Sanjay K Prasad. Department
of CMR, Royal Brompton Hospital, London, UK
Clinical history: A 74 year old female with increasing breathlessness.
Known rheumatic heart disease and LVH.
Cine CMR:
No1. LVOT: mixed aortic and mixed mitral valve disease
No2. cross-cut of mitral valve showing doming of valve leaflets and
mild jet formation during LV filling
No3. short axis of aortic valve. Valve area 0.8cm2.
No4. short axis of mitral valve. Valve area 2.4cm2. Mild MS.
Perspective: CMR provides an alternative to echo for the
assessment of valvular disease.
Equipment: Siemens Avanto
References: Kon MW et al. Quantification of regurgitant fraction
in mitral regurgitation by CMR: comparison of techniques. J Heart Valve Dis.
2004;13:600-7 Maksimovic R et al. Cardiac imaging in rheumatic diseases. Rheumatology
(Oxon). 2006;45:iv26-iv31
Download this as a powerpoint slide here
|